Multi-line 2 ASC Application Software series 4.x

You’re about to download Multi-line 2 ASC Application Software series 4.x

You have chosen to download our software.

Whitin a few seconds, you will receive an e-mail containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

This software applies to the following DEIF products:

You’re about to download 4.18.0

The main changes implemented since the last version are as follows:

PM compatibility version 1.24.1

New features:

  • SinExcel PCS VSG (Droop) support.
  • Breaker feedbacks from Power meter using DEIF control available as M-Logic inputs.
  • New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Havells 80-136kW PV protocol added.
  • Battery only: ESB on sequence configuration menu 2350. Can be used for delaying breaker close based on timer and running status.
  • Solar only: Choice of POA+BOM or GHI+BOM added to Instant Pmax parameter.
  • Solar only: Multiplier for POA/GHI irradiance sensor input now possible using parameter 6305.

Changes:

  • Added inhibits for Ext comm 1 err (Parameter 7520).
  • Added delay timer for BMS comm err (Parameter 7690).

Corrections:

  • Generating and charging capacities on Narada BMS now scaled correctly.
  • The monitoring telegram for SMA Cluster Controller wasn't cycling through the Modbus addresses.
  • Alarm inhibits were not working on some alarms
  • ASC-4 battery now only initiates charging after unit is powered up if SOC is below configured limit.
  • Minor corrections to Ausar MAE and PowerCube BMS protocols.
Ver. Date Description

4.18.0

20/09/2021

PM compatibility version 1.24.1

New features:

  • SinExcel PCS VSG (Droop) support.
  • Breaker feedbacks from Power meter using DEIF control available as M-Logic inputs.
  • New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Havells 80-136kW PV protocol added.
  • Battery only: ESB on sequence configuration menu 2350. Can be used for delaying breaker close based on timer and running status.
  • Solar only: Choice of POA+BOM or GHI+BOM added to Instant Pmax parameter.
  • Solar only: Multiplier for POA/GHI irradiance sensor input now possible using parameter 6305.

Changes:

  • Added inhibits for Ext comm 1 err (Parameter 7520).
  • Added delay timer for BMS comm err (Parameter 7690).

Corrections:

  • Generating and charging capacities on Narada BMS now scaled correctly.
  • The monitoring telegram for SMA Cluster Controller wasn't cycling through the Modbus addresses.
  • Alarm inhibits were not working on some alarms
  • ASC-4 battery now only initiates charging after unit is powered up if SOC is below configured limit.
  • Minor corrections to Ausar MAE and PowerCube BMS protocols.

4.17.1

16/07/2021

PM compatibility version 1.24.1.

Corrections:

1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter.

4.17.0

28/06/2021

PM compatibility version 1.24.1.

New features:

  • ABB SACE Emax 2 protocol (Power meter) is added.
  • Fallback timer for power limit on SunSpec (parameter 2810) is added.
  • DEIF Generic BESS protocol is added.
  • DEIF Generic can now be choosen as a stand-alone BMS protocol.
  • Pylontech PowerCube H1/H2 BMS protocol is added.
  • Phase direction can now be controlled from M-Logic.
  • BMS warning and shutdown alarm (parameters 7610 and 7620) are added.
  • Battery droop logic is added in parameter 2800. (Currently supported by DEIF generic only).
  • Ausar MAE v2 battery protocol is added.
  • Option T1 shortcircuit protection (parameters 2301, 2302, 2303 and 2311) is added.
  • Option T1 redundancy on ASC Battery is added, along with improvements for ASC PV redundancy.
  • CATL BMS protocol is added.
  • FIMER PVS980-58BC battery protocol is added.
  • Support for BMS write telegrams over Modbus is added.

Changes:

  • Added BB volt/freq OK, BB voltage OK, BB frequency OK, PV volt/freq OK, PV voltage OK and PV frequency to M-Logic events.

Corrections:

  • Corrected that Sunspec initialization sometimes fails if the inverter takes too long to set up.
  • When the ASC is a solar unit, it can no longer send negative P-ref set points to the inverter.
  • Corrected that emulation units were not able to start with PV/BESS protocol set to OFF.

4.16.0

08/04/2021

PM compatibility version 1.23.0.

New features:

  • Sungrow Logger 1000 protocol is added.
  • GroWatt PV inverter protocol is added.
  • ATESS Growatt BCU protocol is added.
  • Modbus master communication monitoring tool is added in menu 9080 and to the Input registers at address 53000.

Changes:

  • Improved Q-share and de-load of last online DG.
  • Improved the SunSpec identifying information shown in the display.
  • Listed PV/BESS/PCS/BMS in alphabetic order in the display and in the USW.

Corrections:

  • Corrected: Hybrid controller gets stuck on Sunspec initialization.
  • MB EXTERN TRIPPED warning text removed as the MB is not controlled by the ASC-4.

4.15.1

25/02/2021

PM compatibility version 1.22.0.

Corrections:

  • Derated nominal battery power was not taken into account when calculating charging references.

4.15.0

30/11/2020

PM compatibility version 1.22.0.

New features:

  • Support of the shared parameter for configurable amount of Fatal CAN error alarm.
  • Sinexcel PCS inverter is added.
  • Narada BMS is added.
  • Spinning reserve feature is added. 

4-14-2

29/10/2020

PM compatibility version 1.20.0

Corrections:

  • OEM-specific correction updated.

4.12.0

19/03/2020

PM compatibility version 1.16.0.

New features:

  •    ASC in Load Point.
  •    Parameter for selecting P and Q mode writing when using Sunspec generic. 
  •    Support of Enerflow Inverter.
  •    Support of Delta RPI 88H Inverter.
  •    Support of GPPS Inverter.
  •    Support of BMS.
  •    Support of LFP BMS.
  •    Support of Delta Ohm Weather station.
  •    Support of SMA Sunny Island Inverter.
  •    Support of Evvo Inverter.
  •    Support of Huawei SUN2000 50-60KTL Inverter.
  •    Support of Huawei SUN2000 100-125M0-M2 Inverter.

4.11.3

28/01/2020

PM compatibility version 1.16.0

Corrections:

  • Wrong index in new measurement area for updated Sungrow protocol.

4.11.2

24/01/2020

PM compatibility version 1.16.0

Corrections:

  • ALC power is now a part of the emulation calculation.
  • Sungrow protocol is updated to the newest protocol. 
  • SolidQ protocol is updated to go from 0-110 % range power.  

4.11.1

31/10/2019

PM compatibility version 1.16.0.

Corrections:

  • Sunspec generic protocol is now able to support PVS100/120.

4.11.0

11/12/2018

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

4.10.1

16/04/2018

Corrections:

  • Menu 2150, "Phase Sequence Error" was missing at ASC Solar.

4.10.0

20/03/2018

PM compatibility version 1.16.0

New features:

  • Battery variant
  • Support of SolarEdge inverter
  • Support of Tesla PowerPack inverter 
  • Support of Qinous inverter
  • Support of Vacon8000 inverter
  • Support of Chint 50/60 kW inverter 
  • Support of Chint 14/36 kW inverter 
  • Support of SolidQ 50 inverter
  • Support of SolidQ 60 inverter
  • Support of 16 ASCs, in ID range 25-40
       

Corrections:

  • Power management total power and reactive power readings in Modbus always displayed 0.

4.05.2

12/01/2018

Corrections:

  • Schneider iEM3000 protocol corrected.

4.05.1

02/01/2018

PM compatibility version 1.15.0

Corrections:
1- Fail classes initialised to "Shutdown" unintendedly.

 

4.05.0

30/11/2017

PM compatibility version 1.15.0

New features:

  • Support of 16 mains energy meter.
  • Support of Socomec Multis L40 energy meter.
  • Support of EDS MMT3(5A) energy meter.  
  • Support of Gossen mavalog energy meter.
  • Support of EDMI energy meter.
  • Support of calculated PF and kVA based on energy meter data. 
  • Support of Reuniwatt SkyInSight.
  • Support of Ginlong Solis inverter.

Corrections:

  • The ASC will not try to close after it is tripped due to under-voltage coil.

Changes:

  • Socomec Multis L40 changed to Socomec Diris a40. 
  • Generic SunSpec protocol updated. Unknown maker specific models no longer interpreted by the ASC as SunSpec map being incompatible.

 

4.04.0

05/10/2017

PM compatibility version 1.15.0

New features:

1- Support of HiQ inverter.
2- Support of IngeTeam inverter.
3- Support of Schneider PM5560 energy meter.
4- Support of Socomec Multis L40 energy meter.

4.03.1

09/05/2017

PM compatibility version 1.15.0

Corrections:

  • Correction to “Re-initialisation of PV inverter protocol made robust”.
  • PV Monitoring functionality malfunctioning in SunSpec protocol.

4.03.0

03/04/2017

Version 4.03.0
PM compatibility version 1.15.0

New features:

  • Support of short-term weather forecast system, SteadyEye, from SteadySun.

Changes:

  • "SMA SunSpec" protocol selection text changed to "SMA SunSpec v2.82". 

Corrections:

  • Re-initialisation of PV inverter protocol made robust.
  • PV curtailment "Yearly" counter displayed garbage.

 

4.02.0

21/12/2016

PM compatibility version 1.15.0

New features:

  • Support of Modbus-based power meters.
  • Support of DG and mains power readings via DEIF open protocol.
  • Support of GB/MB breaker feedbacks via M-Logic.
  • Support of INVT BG series inverter.
  • Mains kWh counters added.

Changes:

  • Option M4 made optional

Corrections:

  • Delta RPI interface corrected.
  • PV monitoring data could not be read via service port or H2.
  • MBON status not working in M-Logic.
  • Minimum genset load could not be accessed if Option G5 is not present.
  • Minimum genset load setting control from M-Logic did not work

Como sempre, recomendamos a instalação dos aprimoramentos oferecidos para que você possa desfrutar totalmente do seu produto DEIF.

Todos os softwares aprimorados podem ser baixados, à sua conveniência e de maneira gratuita pelo site www.deif.com sob a opção “Software” e, em seguida, “Software Download”.

Em caso de dúvidas ou se enfrentar problemas para encontrar o software relevante para o seu produto, fique à vontade para contatar a DEIF A/S pelo telefone + 45 96149614 ou no escritório local da DEIF. Como alternativa, você pode enviar um e-mail para support@deif.com. Estamos sempre prontos para ajudar!