PM compatibility version 1.20.0

Corrections:

  • OEM-specific correction updated.

Versão. Data Descrição

4.14.2

29/10/2020

PM compatibility version 1.20.0

Corrections:

  • OEM-specific correction updated.

4.14.0

23/09/2020

PM compatibility version 1.20.0

New features: 

  • Samsung BMS protocol implemented 
  • Sungrow PCS protocol implemented 
  • T1 option added.

Corrections:

  • Corrected, problems with communication towards M4 (Affecting PMS and redundancy)
  • Corrected, DG Reverse Power Alarm 2 Inhibit not working
  • Reliability data temperature correction (And reliability data on webarm)

4.13.0

23/09/2020

PM compatibility version 1.16.0.

New features: 

  • Y-Cube protocol is added.

4.12.0

19/03/2020

PM compatibility version 1.16.0.

New features:

  •    ASC in Load Point.
  •    Parameter for selecting P and Q mode writing when using Sunspec generic. 
  •    Support of Enerflow Inverter.
  •    Support of Delta RPI 88H Inverter.
  •    Support of GPPS Inverter.
  •    Support of BMS.
  •    Support of LFP BMS.
  •    Support of Delta Ohm Weather station.
  •    Support of SMA Sunny Island Inverter.
  •    Support of Evvo Inverter.
  •    Support of Huawei SUN2000 50-60KTL Inverter.
  •    Support of Huawei SUN2000 100-125M0-M2 Inverter.

4.11.3

28/01/2020

PM compatibility version 1.16.0

Corrections:

  • Wrong index in new measurement area for updated Sungrow protocol.

4.11.2

24/01/2020

PM compatibility version 1.16.0

Corrections:

  • ALC power is now a part of the emulation calculation.
  • Sungrow protocol is updated to the newest protocol. 
  • SolidQ protocol is updated to go from 0-110 % range power.  

4.11.1

31/10/2019

PM compatibility version 1.16.0.

Corrections:

  • Sunspec generic protocol is now able to support PVS100/120.

4.11.0

11/12/2018

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

4.10.1

16/04/2018

Corrections:

  • Menu 2150, "Phase Sequence Error" was missing at ASC Solar.

4.10.0

20/03/2018

PM compatibility version 1.16.0

New features:

  • Battery variant
  • Support of SolarEdge inverter
  • Support of Tesla PowerPack inverter 
  • Support of Qinous inverter
  • Support of Vacon8000 inverter
  • Support of Chint 50/60 kW inverter 
  • Support of Chint 14/36 kW inverter 
  • Support of SolidQ 50 inverter
  • Support of SolidQ 60 inverter
  • Support of 16 ASCs, in ID range 25-40
       

Corrections:

  • Power management total power and reactive power readings in Modbus always displayed 0.
 

4.05.2

12/01/2018

Corrections:

  • Schneider iEM3000 protocol corrected.

4.05.1

02/01/2018

PM compatibility version 1.15.0

Corrections:
1- Fail classes initialised to "Shutdown" unintendedly.

 

4.05.0

30/11/2017

PM compatibility version 1.15.0

New features:

  • Support of 16 mains energy meter.
  • Support of Socomec Multis L40 energy meter.
  • Support of EDS MMT3(5A) energy meter.  
  • Support of Gossen mavalog energy meter.
  • Support of EDMI energy meter.
  • Support of calculated PF and kVA based on energy meter data. 
  • Support of Reuniwatt SkyInSight.
  • Support of Ginlong Solis inverter.

Corrections:

  • The ASC will not try to close after it is tripped due to under-voltage coil.

Changes:

  • Socomec Multis L40 changed to Socomec Diris a40. 
  • Generic SunSpec protocol updated. Unknown maker specific models no longer interpreted by the ASC as SunSpec map being incompatible.

 

4.04.0

05/10/2017

PM compatibility version 1.15.0

New features:

1- Support of HiQ inverter.
2- Support of IngeTeam inverter.
3- Support of Schneider PM5560 energy meter.
4- Support of Socomec Multis L40 energy meter.

4.03.1

09/05/2017

PM compatibility version 1.15.0

Corrections:

  • Correction to “Re-initialisation of PV inverter protocol made robust”.
  • PV Monitoring functionality malfunctioning in SunSpec protocol.

4.03.0

03/04/2017

Version 4.03.0
PM compatibility version 1.15.0

New features:

  • Support of short-term weather forecast system, SteadyEye, from SteadySun.

Changes:

  • "SMA SunSpec" protocol selection text changed to "SMA SunSpec v2.82". 

Corrections:

  • Re-initialisation of PV inverter protocol made robust.
  • PV curtailment "Yearly" counter displayed garbage.
 

4.02.0

21/12/2016

PM compatibility version 1.15.0

New features:

  • Support of Modbus-based power meters.
  • Support of DG and mains power readings via DEIF open protocol.
  • Support of GB/MB breaker feedbacks via M-Logic.
  • Support of INVT BG series inverter.
  • Mains kWh counters added.

Changes:

  • Option M4 made optional

Corrections:

  • Delta RPI interface corrected.
  • PV monitoring data could not be read via service port or H2.
  • MBON status not working in M-Logic.
  • Minimum genset load could not be accessed if Option G5 is not present.
  • Minimum genset load setting control from M-Logic did not work

Como sempre, recomendamos a instalação dos aprimoramentos oferecidos para que você possa desfrutar totalmente do seu produto DEIF.

Todos os softwares aprimorados podem ser baixados, à sua conveniência e de maneira gratuita pelo site www.deif.com sob a opção “Software” e, em seguida, “Software Download”.

Em caso de dúvidas ou se enfrentar problemas para encontrar o software relevante para o seu produto, fique à vontade para contatar a DEIF A/S pelo telefone + 45 96149614 ou no escritório local da DEIF. Como alternativa, você pode enviar um e-mail para support@deif.com. Estamos sempre prontos para ajudar!